Release Notes

CHEMCAD NEW FEATURES AND ENHANCEMENTS

  • Upgraded CHEMCAD’s optimization tools with more robust objective function input, improved calculation, multi-objective optimization, Pareto front visualization, and more reliable global optima
  • Added the capability for CHEMCAD NXT to use a multi-core processor to improve calculation speed (4914)
  • Rewrote the CHEMCAD calculation engine to improve speed, convergence stability, and thermodynamic calculations
  • Implemented the Raschig 2009 packing model as a new packing method for mass transfer column sizing and rating (4169)
  • Enhanced the Stream and UnitOp Starting IDs feature to allow entry of alpha-numeric prefix values (6703)
  • Added an option to the Sensitivity Analysis report and chart to filter any points that did not converge (4779/7084)
  • Added the capability to run a selected UnitOp, a group of UnitOps, or a recycle loop from the OPC client (5801)
  • Added the capability for the Meta UnitOp to reference a relative file path to a child simulation (6098)
  • Removed limitations on total number of streams that can connect to UnitOps with large numbers of inlet and outlet ports (1061)
  • Added the option to export a Data Map (4115)
  • Simplified use of the Scale option for the objective function in the Optimization and Data Reconciliation tools (5259)
  • Provided easy access to all user-added module (UAM) documentation, libraries, and files in the Chemstations directory (6244)
  • Exposed the CHEMCAD solver to the UAM environment (6443)
  • Improved reporting of mass transfer HETP for the Billet & Schultes and Raschig 2009 packing sizing methods (6798)

CHEMCAD USER INTERFACE

  • Implemented a new ribbon-based command structure for CHEMCAD (5767/6154)
  • Increased the limit for stream names to 100 characters (1006)
  • Implemented automatic update of relevant UnitOp settings when a referenced stream or UnitOp ID changes (1280)
  • Improved the RAMP UnitOp with a grid interface that supports up to 5000 entries and makes it possible to copy and paste data to and from Excel (3522/5241/7360)
  • Redesigned the Engineering Units dialog to improve ease of use (4909)
  • Implemented a 3-D surface chart for use with the Sensitivity Analysis tool (5056)
  • Improved the Control Valve UnitOp specification modes for ease of use (7267/7272)
  • Added the capability to select all text boxes and databoxes on a flowsheet with a single click to apply font changes (6686/7030)
  • Added the capability to specify a default font for all flowsheet databoxes (7029)
  • Added a message in the status bar to indicate when a simulation’s results are converged (366)
  • Changed the behavior of the Auto Pan feature so that it remains active until the user turns it off (6181)
  • Improved the performance of the E-mail Simulation feature (6255/6939)
  • Corrected an issue where the Zoom to Fit feature did not function as expected after flowsheet objects were moved to a new location (6837)
  • Made fixed-flow modes in the Divider, Stream Reference, Vessel, and Tank UnitOps consistent and independent of time engineering units (6840)
  • Enabled the Snap to Center setting for drawing by default (6870)
  • Added numerous drawing tools for use in the main CHEMCAD workspace and the UnitOp Designer tool (5959/6877)
  • Replaced the "Run one time step for dynamic simulation" option in Convergence Parameters with an easily accessed command on the Home tab (7012)
  • Improved the selection of variables to plot on a sensitivity analysis chart (7088)
  • Added a Windows Registry key setting that preserves the user’s palette settings during CHEMCAD updates (7197)
  • Adjusted the Edit Streams dialog to prevent overlapping command buttons (7209)

CC-THERM

  • Added a zone-by-zone analysis calculation for a sensible-sensible case (2405)

CC-DYNAMICS

  • Added full zoom capabilities to completed runtime charts (3897)
  • Prevented runtime charts that are closed during a dynamic run from reopening (7081)
  • Added the capability for the META UnitOp to run in a dynamic simulation (2386)
  • Corrected an issue where the runtime chart in a Batch Reactor dynamic simulation could cause CHEMCAD to close unexpectedly (5052)

CHEMCAD PHYSICAL PROPERTIES

  • Added new chemicals from the DIPPR Lite May 2019 and May 2020 databases into CHEMCAD (6993/7327)
  • Resolved several entries in the CHEMCAD database where a physical property was incorrectly being calculated from another property’s equation (7045)
  • Corrected an error in the specific gravity values of some components (6992)
  • Added 3M Novec 649 to the CHEMCAD component database (4944)
  • Added Eastman Chemical Co. heat transfer fluids (Therminol) to CHEMCAD database (5604)
  • Corrected the Gibbs of formation for boron trichloride (BCl3) and other components (6582)
  • Corrected component data for 932 Ammonium Chloride (7053)
  • Corrected the DIPPR vapor pressure for 1,3-Diaminopropane (CAS RN® 109-76-2, ID 1875) (7117)
  • Corrected the DIPPR heat of formation for 2-Phenyl-2-Propanol (CAS RN® 617-94-7, ID 1440) (7126)
  • Corrected an issue that could prevent the molecular weight of a user component from updating as needed when the component’s formula was changed (7022)
  • Implemented verification of component CAS RN® number on entry of a user-added component (7273)

CHEMCAD MAINTENANCE

  • Added a new option to the Kinetic Reactor UnitOp for counter-current PFR utility calculation of either the inlet or outlet temperature (137/5189)
  • Corrected an issue where the User Component report did not include all the Antoine vapor pressure coefficients for a user-added component (4748)
  • Corrected an issue with the "Resize the column after each run" option not working for packed columns (4772)
  • Corrected an issue where the Excel Data Map feature could not pass a range of cells for data reconciliation (4795)
  • Corrected an issue where the Maurer thermodynamic model could predict an invalid enthalpy value for a mixture of nitrogen and oxygen (4903)
  • Corrected an issue where the Stream Reference UnitOp did not adjust its own feed stream (5109)
  • Corrected an issue where a META UnitOp did not account for a child UnitOp having different thermodynamic settings (5142)
  • Corrected an issue where displaying an equilateral triangle plot could cause CHEMCAD to reinstall Windows components (5167)
  • Corrected an issue where the Wilson activity coefficient model could flash streams incorrectly when used as a local thermodynamic model (5220)
  • Corrected an issue with the Maurer K-value model predicting invalid activity coefficients (5251)
  • Corrected an issue where a solid component could be included in vapor/liquid transport property calculations (5558)
  • Corrected issues with the Compressor and Expander UnitOps to check actual power and efficiency only when entered by the user (5668)
  • Corrected an issue with generation of the Excel interface file when that option is selected for packing sizing (5933)
  • Corrected the NTS data that displays in the Excel interface file for packed column sizing (3448)
  • Corrected an issue with mass balance calculation in the Vessel Reactor UnitOp (6049)
  • Corrected a Japanese translation issue for the binodal plot (6071)
  • Corrected an issue with the VTPR equilibrium calculation that could occur when Water/Hydrocarbon Solubility was set to Immiscible (6202)
  • Changed the reference density for automatic estimation of VTPR ci constant (6941)
  • Corrected an issue where opening a simulation that used VTPR for local thermodynamics could cause CHEMCAD to close unexpectedly (6695)
  • Allowed sizing and cost calculations concurrently with the relevant UnitOps, instead of at the end of the flowsheet run (6260)
  • Corrected an issue with the Tray Composition report so that mass fractions are reported (6316)
  • Disabled the ports on UnitOp symbols while the Select UnitOps or Select Streams dialog is open, to prevent accidental port connections while clicking on flowsheet items (6322)
  • Corrected specific heat conversion calculations for kJ/gmol in the Engineering Units Converter (6332)
  • Revised the Heat Exchanger UnitOp costing algorithm for long tubes or falling film evaporator exchanger types (6358)
  • Corrected an issue where CHEMCAD could report liquid volume percentage as liquid volume fraction (6370)
  • Corrected an issue where the Loop UnitOp did not take local thermodynamic settings into account (6491)
  • Added the capability to change the reported engineering units for mass transfer sizing dP/m values (6542)
  • Corrected an issue with the Pipe UnitOp that triggered a warning message about the Baker graph under certain conditions (3754)
  • Changed the default behavior of the Pipe UnitOp to use the Beggs and Brill method, rather than the Baker method (6821)
  • Corrected an issue where a Pipe UnitOp with heat transfer and elevation specified could calculate invalid outlet stream values (7249)
  • Corrected an issue where the calculated velocity in the pipe sizing report did not match the flowsheet value (6620)
  • Removed support for the SPEAD model (6661)
  • Corrected an issue where the Vessel Reactor UnitOp could ignore SLE (6666)
  • Corrected an issue where a VLLE Flash UnitOp could ignore SLE in the light liquid phase (6668)
  • Corrected an issue where legacy flow units could override a user’s property set selection (6814)
  • Changed the extrapolation behavior of the Ramp UnitOp (6824)
  • Corrected an issue with reporting of SCDS UnitOp with reactive distillation to report actual reaction volume values (6851)
  • Expanded real-time reporting of UnitOp warning and error messages in the Messages pane (6872)
  • Corrected a Flash UnitOp issue where running an isentropic flash could cause changes to the calculated entropy value (6878)
  • Corrected an issue with some solids handling UnitOps interacting incorrectly with the SLE thermodynamic setting (6907)
  • Corrected an issue with the partial pressure calculation when a weight fraction is selected on the TPXY X-axis option (6958)
  • Corrected an issue with the Relief Valve UnitOp non-flashing liquid mode option (6975)
  • Corrected an issue with the Print Component Data report that could occur with components created using UNIFAC correlation (7129)
  • Corrected issues with the TOC/COD tool interface (7152, 7153, 7154)
  • Updated the UsrEqn1001.sf file, to provide clearer instructions on creating a user-added transport property equation (7245)
  • Corrected an issue that could cause a custom property set with a blank name to unexpectedly close CHEMCAD (7252)
  • Corrected an issue where the User Components report output to Excel could skip some lines of data (7258)
  • Corrected an issue where Heat Exchanger costing was based on calculated area, rather than zone analysis area, for an exchanger with multiple zones (7264)
  • Updated costing index with May 2020 published values (7349)
  • Improved convergence for SRK and Peng-Robinson thermodynamic models with supercritical fluids (7357)
  • Corrected an issue where the Save As command did not save changes if the simulation name was not changed (7363)
 

Minimum System Requirements

We recommend the following system configurations so you can experience the best that CHEMCAD has to offer:

  • Processor speed: 1 GHz or faster, 32- or 64-bit
  • Operating system: Windows 7 or later (all 32- and 64-bit versions)
  • RAM: 1 GB for 32-bit, or 2 GB for 64-bit
  • Video card: DirectX 9 graphics device with WDDM 1.0 or higher driver
  • Display resolution: 1920 x 1080 or higher
  • Hard disk space: 16 GB (32-bit) or 20 GB (64-bit) for installation,
    1 GB free space recommended
  • Productivity software: Some features require Microsoft Office®